Servo motor cable to relieve stress

 Electric Motors 1 HP 3PH
Specifications
1. Shape: squirrel cage
2. CE.ISO CCC 
3. Side Terminal Box 
4. Free Foot Mounting 
5. 100% copper wire 
A: to ensure that the cable is not because of external bending force or under vertical load torque or its spare parts weight, especially in the cable or joint at the exit. B: in the case of a servo motor to move, should put cable (that water pump price is, with the motor configuration) is firmly fixed diesel magnetic generator single phase motor generator to a stationary part (motor), and small diesel engine should use an additional cable installed in synchronous generator the cable support to prolong it, so www.dongfeng-motor.com that the ac induction motor bending stress can be reduced to a minimum. C: the diesel generator set bend radius of the cable to be as large as possible.

2014年11月18日星期二

How to choose and switch

 Cast Iron electrical motor auto spare parts 
Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality
3. Delivery Detail:within 10 days after receiving deposit 
Switches as the main equipment of the network connection, determines the performance and stability of the network itself. Along with the company size is different, the structure of the network also has the very big difference, the switch must also depends on the specific circumstances, but in order to make the company can undertake a large number of network data transmission and lasting stable running safely, must choose to comply with the 3 phase ac induction motor performance of the conditions and price appropriate switches. Personally, electric motor parts I engaged in this work for a while, the technology and properties of the current switch has some basic views, the hope can give you some reference: 


OEM industrial electric motors
Specifications
1. effiency: IE2 and IE1 
2. 20 years manufacturing experience 
3. 12 months guarantee 

4. low noise and vibtration
Switches in recent years there are a lot of new technology, some technology is very useful. (1), Trunking, Trunking technology can be without changing the existing network equipment and wiring of the original conditions, multiple low bandwidth will switch ports bundled into a high bandwidth link exchange, through several port link load balancing, avoiding the phenomenon of link congestion. In the part of the company's network backbone equipment can use this technology: the network traffic is bigger, but actual condition is not allowed to use under the condition of cable, using Trunking can solve the bottleneck problem of data transmission. Induction motor (2), the third layer switch based on the development of the fourth layer switches. This is a relatively new feature, introduce in detail here.

2014年11月17日星期一

A two-speed motor variable speed principle

Cast Iron electrical motor auto spare parts 
Specifications
1. 20 years manufacturing experience 
2. competitive price,high quality

3. Delivery Detail:within 10 days after receiving deposit 
Variable speed of the motor by changing winding single phase motor connection mode, that is to say, with a rotating magnetic field of magnetic pole change motor logarithmic to change its speed. If your unit's Electric motor two-speed motor (fan), low speed at ordinary times, sometimes fan on high speed turning, mainly through external control circuit switch to change the motor coil winding connection. 1, there are two different embedded in the stator slot logarithm of winding, by changing the external control line to change of motor stator winding connection to realize the logarithm change poles; 2, in the stator slot electric generator embedded, there are two different polar logarithmic independent winding; 3, in the stator slot is embedded, there are two different logarithmic independent winding, and each winding can have different connection again.

2014年10月27日星期一

A direct torque control system


 The characteristics of the direct torque control is to control the stator flux linkage, is directly under the stator static coordinate system, with space vector concept, by detecting the stator voltage, current, direct calculation under the stator coordinate and control the flux linkage and torque of the motor, torque, high dynamic performance. It does not require the ac motor into equivalent dc motor, and thus eliminate the vector transformation of many complex calculations, it does not need to imitate the ac motor capacitor dc motor control, and thus do not need for decoupling and simplify the mathematical model of ac motor, and just care about the size of the electromagnetic torque and so on in addition to the stator resistance of all control motor parameters change good robustness, the stator flux observer is introduced by magnetic chain model can easily, and conveniently estimate the synchronous speed information, at the same time is also very easy to get torque model, flux model and torque model would constitute the complete motor model, and thus can easily achieve speed spare parts sensorless control, if again set the speed regulator in the system, can be further high-performance dynamic torque control. 

To be sure, the direct torque control inverter with different switching device, control method is also different. Depenbrock initially proposed directly from the control theory, mainly in the high voltage, high power and low switching frequency inverters are widely used in the control. Current control method is applied to general inverter is a kind of improvement, suitable for high switching frequency inverters. ABB company first launched in 1995 ACS600 series general inverter direct torque control system, the dynamic torque response speed has reached < 2 ms, when the belt speed sensor PG 0.001% rate of static accuracy of soil, in the case of without speed sensor PG even affected by the change of the input voltage or load mutation, also can be plus or minus 0.1% of the speed control accuracy. Other companies also is trying to target with direct torque control, such as Fuji company FRENIC5000VG7S series high performance electricalmotor1.blogspot.com speed sensorless vector control of general frequency converter, with direct torque control method and difference, but it also has to do the speed control accuracy + / - 0.005%, 100 hz and 800 hz current response speed response and torque control accuracy + / - 3% (PG). Other companies such as Japan's mitsubishi, Hitachi, the latest series of products such as Finland VASON speed sensorless control of similar design, performance have further improved.

Ac voltage measurement

 In order to grasp the change situation of IC ac signal,can be used with the dB jack multimeter ac electric motor 12v 500w voltage electrical motor 24v to approximate measure of IC.Detection multimeter under ac voltage blocking,pens and insert the dB jack;For no dB jack multimeter,need in pens and concatenated a 0.1 ~ 0.5 u F condenser.The method is suitable for the working frequency is low IC,such as television video amplifier stage,field scanning circuit,etc.Due to acmotortrading.blogspot.com the inherent frequency of the circuit,waveform is different,so the measured data is an approximation,for reference only.

2014年10月12日星期日

Using logical analysis to identify and narrowing the scope of the fault


Maintenance simple electrical control circuit,to each of the electrical components one by one to inspect each wire,usually can quickly find the point of failure.But for complex circuit,often have hundreds of components,thousands of wire,if to examine' method,not only need to spend a lot electrical motor of time,but also easy to leak check.If in this case,according to the circuit diagram,using logical analysis,make concrete analysis of the fault phenomena,to draw suspicious range,improve the maintenance of the targeted,can receive motor run capacitor the accurate and fast effect.

Analysis circuit first,from the perspective of the main circuit,realize the industrial machinery using a few moving parts and electric motor drive,what are related to each motor electrical components,what control adopted,electricalmotor1.blogspot.com and then according to the electric main circuit of the circuit element used text symbols,sex and control requirements,find the corresponding control control circuit.On this basis,combining with the failure phenomena and circuit principle of asynchronous motor work,careful analysis of the screen,can quickly determine the possibility of failure.When fault suspicious range larger,don't need to check step by step,step by step then can be in the range of failure in a check of the intermediate links,to judge the fault occurred where on earth is part of thus narrowing the scope of failure,improve the inspection speed.

2014年9月18日星期四

The dc grounding method


A independent grounding:as discussed above the needs of the grounding part,each independently set up their own grounding system,the grounding method,called independent grounding.It has the advantage of not cause mutual interference between each system,it is especially important for communication system.But the network is liable to be struck by lightning bad,so in addition to is in danger of explosion proof requirements must adopt independent way of lightning protection of the environment,generally do not adopt the way of independent grounding.This independent grounding in the 60 s and seventy s before use is more,now replaced by common ground.Second,common ground:also called unified wholesalemotor.blogspot.com grounding.

It is unified all the need for grounding system receives a grounding device,or the original
grounding device each system through underground or on the ground with a metal conductor
connected,make them ac electric motorsbecome smooth electrical grounding network,between the grounding method for common ground.Common grounding is currently the most widely used.Three,one-point earthing:each system grounding line connects to ground strap the same point or the same metal plane,one-point earthing method can solve the potential ac alternators 220v problems such as ground wire of each system,so can reduce the degree of interference between each system,especially the electric motors price 50 hz power frequency signal to eliminate interference on the system basically,so a little grounding method is widely used in engineering.A little grounding eliminates common impedance coupling and low frequency interference caused by ground loop.Can work well in more than 1 MHZ and frequency,when the size of the whole system is small (maximum size less than 20,l/l for jamming signal wavelength) can be applied to the 10 MHZ.

2014年8月27日星期三

Three-phase asynchronous motor open phase fault operation


1,the lack of the phenomenon of phase operation Three-phase asynchronous motor 220v ac electric motors open phase running "refers to a three phase power supply phase lack a phase or three phase winding of the motor circuit there is a phase in the motor caused by abnormal running state also called open phase running. Destroyed most of the three-phase asynchronous motor winding is caused by motor open phase running,when the motor is in a state of overload,under the same load power,lack of phase running current rotor and stator is higher than normal operation of the current times.At this point,if not handled in time,motor winding will be burned.If the motor before starting circuit,a phase may only after turning on the power single phase capacitor start induction motorsupply noise is not www.facebook.com/guohong.trading
starting,must cut off the power immediately,otherwise,will burn winding.

2014年8月24日星期日

Motor fault..



1 Phenomenon: starting controller cannot be started.Methods: 1,grounding detection,normal. 2,control cabinet,soft start fault,starting current is not normal.3,replace the soft wholesalemotor.blogspot.com starter.4,phenomena,and 2.5,measuring and motor resistance,resistance to 0.Lazy day,I turned out to be workers,only measuring grounding resistance,no resistance value between test items,we water pump motor checked for a long time,thought it was a soft starter is broken,the www.facebook.com/guohong.trading terminal box at the original are all connected to the motor power cable to cut off,oh my god,can single phase induction motor my bitter pit,sorching summer I stayed for two days on site in sewage mosquitoes can calculate to see blue.Other: if the motor is good for fire insurance,it must be soft starter is broken.